Four-corner arthrodesis: description of surgical technique using headless retrograde crossed screws
Loading...
Date
Journal Title
Journal ISSN
Volume Title
Publisher
American Association for Hand Surgery
Abstract
Objective: Four-corner fusion has been shown to be a reliable option of treatment of wrist arthritis, but there is no consensus about which implant and surgical procedure should be used in the arthrodesis. The present study aimed to describe a surgical technique using 2 crossed screws as implants, inserted in a retrograde manner, and to demonstrate preliminary results of the use of the technique.
Methods: A retrospective study was conducted using medical records and imaging tests (radiographs and computed tomography) of all 15 patients who underwent a standardized 4-corner fusion technique, between December 2011 and July 2015, in the Department of Hand Surgery of Instituto Nacional de Traumatologia e Ortopedia (INTO), Rio de Janeiro, Brazil. We collected data on the following variables: fusion rate, time to fusion, and percentage of patients who had any complications or needed another surgical procedure on the same wrist.
Results: All but one patient achieved fusion of arthrodesis. The average time to union was 5.54 months (SD = 3.84). Only the patient who developed nonunion of the 4-corner fusion required another surgery on the same wrist.
Conclusions: The procedure described in this study demonstrated a low complication rate and high fusion rate, and can therefore be considered a reliable surgical technique for 4-corner fusion.
Description
Keywords
Citation
MAMEDE, João; ADEODATO, Sandro Castro; LEAL, Rafael Aquino. Four-corner arthrodesis: description of surgical technique using headless retrograde crossed screws. American Association for Hand Surgery. [S. l.]. v.13. S2. p156–163. 2018 DOI 10.1177/1558944717702468