Four-corner arthrodesis: description of surgical technique using headless retrograde crossed screws
| dc.contributor.author | Mamede, João | |
| dc.contributor.author | Adeodato, Sandro Castro | |
| dc.contributor.author | Leal, Rafael Aquino | |
| dc.date.accessioned | 2026-01-29T14:11:48Z | |
| dc.date.issued | 2018 | |
| dc.description.abstract | Objective: Four-corner fusion has been shown to be a reliable option of treatment of wrist arthritis, but there is no consensus about which implant and surgical procedure should be used in the arthrodesis. The present study aimed to describe a surgical technique using 2 crossed screws as implants, inserted in a retrograde manner, and to demonstrate preliminary results of the use of the technique. Methods: A retrospective study was conducted using medical records and imaging tests (radiographs and computed tomography) of all 15 patients who underwent a standardized 4-corner fusion technique, between December 2011 and July 2015, in the Department of Hand Surgery of Instituto Nacional de Traumatologia e Ortopedia (INTO), Rio de Janeiro, Brazil. We collected data on the following variables: fusion rate, time to fusion, and percentage of patients who had any complications or needed another surgical procedure on the same wrist. Results: All but one patient achieved fusion of arthrodesis. The average time to union was 5.54 months (SD = 3.84). Only the patient who developed nonunion of the 4-corner fusion required another surgery on the same wrist. Conclusions: The procedure described in this study demonstrated a low complication rate and high fusion rate, and can therefore be considered a reliable surgical technique for 4-corner fusion. | |
| dc.identifier.citation | MAMEDE, João; ADEODATO, Sandro Castro; LEAL, Rafael Aquino. Four-corner arthrodesis: description of surgical technique using headless retrograde crossed screws. American Association for Hand Surgery. [S. l.]. v.13. S2. p156–163. 2018 DOI 10.1177/1558944717702468 | |
| dc.identifier.issn | 1558-9455 | |
| dc.identifier.uri | https://ortobase.into.saude.gov.br/handle/123456789/426 | |
| dc.language.iso | en | |
| dc.publisher | American Association for Hand Surgery | |
| dc.subject | Four-Corner Fusion | |
| dc.subject | Surgical Technique | |
| dc.subject | Screws | |
| dc.subject | Slac | |
| dc.subject | Snac | |
| dc.subject | Arthrodesis | |
| dc.subject | Hand Surgery | |
| dc.title | Four-corner arthrodesis: description of surgical technique using headless retrograde crossed screws | |
| dc.type | Article |