Correlation between single-pulse and pulse-train stimulation during neuromonitoring of thoracic pedicle screws in scoliosis surgery
| dc.contributor.author | Silva, Luis Eduardo Carelli Teixeira da | |
| dc.contributor.author | Almeida, Luiz Eduardo de | |
| dc.contributor.author | Cabrera, Juan Pablo | |
| dc.contributor.author | Khan, Ahsan Ali | |
| dc.contributor.author | Mendonça, Maria L. | |
| dc.contributor.author | Vital, Robson Teixeira | |
| dc.contributor.author | Fonseca, Giuliana Vasconcelos | |
| dc.contributor.author | Jardim, Marcia M. | |
| dc.date.accessioned | 2026-08-27T17:49:03Z | |
| dc.date.issued | 2022 | |
| dc.description.abstract | Objective: The use of thoracic pedicle screws (TPSs) during scoliosis surgery entails an inherent risk of neurological deficit. Triggered electromyography (t-EMG) is an accurate neuromonitoring test for detection of malpositioned TPSs. However, single-pulse (SP) t-EMG stimulation has shown variable capability for detecting medial pedicle breaches, while pulse-train (PT) t-EMG could be more accurate. The aim of this study was to analyze the correlation between SP t-EMG and PT t-EMG. Methods: This retrospective study included 20 patients who underwent scoliosis correction with 294 TPSs placed. A total of 588 tests with both SP t-EMG and PT t-EMG were performed, analyzed, and compared. The results of both tEMG techniques were stratified into 3 different groups according to threshold obtained: group 1 (£6 mA), group 2 (6.1e11.9 mA), and group 3 (12 mA). A generalized linear model was used to analyze the correlation between the methods. Results: SP t-EMG elicited response in 5 screws (1.7%) at £6 mA, 28 screws (9.5%) at 6.1e11.9 mA, and 261 screws (88.8%) at 12 mA. PT t-EMG elicited response in 16 screws (5.4%) at £6 mA, 30 screws (10.2%) at 6.1e11.9mA, and 248 screws (84.4%) at 12 mA. There is a strong positive and significant association between SP t-EMG and PT t-EMG with a decrease ratio of 2% (95% confidence interval 1% to 3%). Conclusions: SP t-EMG and PT t-EMG stimulation techniques had similar results when the stimuli were applied to TPSs, but PT t-EMG may have better efficacy in low-threshold group. | |
| dc.identifier.citation | SILVA, Luis Eduardo Carelli Teixeira da; ALMEIDA, Luiz Eduardo de; CABRERA, Juan Pablo; KHAN, Ahsan Ali; MENDONÇA, Maria L.; VITAL, Robson Teixeira; FONSECA, Giuliana Vasconcelos; JARDIM, Marcia M. Correlation between single-pulse and pulse-train stimulation during neuromonitoring of thoracic pedicle screws in scoliosis surgery. World Neurosurgery. United States. v.164. p611-618. 2022. | |
| dc.identifier.doi | 10.1016/j.wneu.2022.05.023 | |
| dc.identifier.issn | 1878-8769 | |
| dc.identifier.uri | https://ortobase.into.saude.gov.br/handle/123456789/759 | |
| dc.language.iso | en | |
| dc.publisher | World Neurosurgery | |
| dc.subject | Neuromonitoring | |
| dc.subject | Pulse-Train | |
| dc.subject | Scoliosis | |
| dc.subject | Single-Pulse | |
| dc.subject | T-EMG | |
| dc.subject | Thoracic Pedicle Screws | |
| dc.title | Correlation between single-pulse and pulse-train stimulation during neuromonitoring of thoracic pedicle screws in scoliosis surgery | |
| dc.type | Article |