Aplicação do dispositivo de avaliação pressórica na transferência de carga entre os membros inferiores nas doenças unilaterais do joelho

dc.contributor.authorVillardi, Alfredo Marques
dc.contributor.authorVillardi, Ciríaco
dc.contributor.authorCamanho, Gilberto Luis
dc.contributor.authorCagy, Maurício
dc.date.accessioned2026-02-06T11:27:40Z
dc.date.issued2006
dc.description.abstractObjetivo: Avaliar comparativamente a distribuição estática de carga dos membros inferiores (MMII) em portadores de doenças unilaterais do joelho e em indivíduos saudáveis. Método: Utilizando o dispositivo de avaliação pressórica (DAP), desenvolvido pelos autores, a partir do método do esfigmomanômetro modificado, no período entre janeiro e março de 2002, foram avaliados 40 indivíduos, com idade variando entre 25 e 66 anos, divididos em dois grupos, sendo o grupo I composto por portadores de doença unilateral do joelho, com queixas de dor, e o grupo II, por voluntários sem história de doença ou sintomas nos membros inferiores. O DAP consiste em uma base de acrílico, sobre a qual são fixadas duas outras placas também de acrílico. Entre a base e cada placa superior, foi introduzida uma bolsa inflável de esfigmomanômetro, sendo a leitura da pressão dos MMII feita nos dois aneróides analógicos. Resultado: No grupo I, a diferença média dos valores pressóricos entre os membros sadio e acometido foi de 30,15mmHg. No grupo I, a média das pressões no membro sadio foi significativamente maior que a média no membro acometido (p < 0,05). No grupo II, não houve diferença significativa entre as médias de pressão dos membros dominante e contralateral (p = 0,14). A assimetria média do grupo I foi de 15,61%, enquanto que no grupo II, de apenas 0,72%. Conclusão: A avaliação da distribuição estática de pressões dos MMII leva a concluir que existe transferência de cargas do membro inferior portador de doença do joelho para o membro contralateral. Objective: To compare the static load distribution in lower limbs (MMII), in individuals with unilateral knee pathologies and in healthy individuals. Methods: Using a pressure evaluation device (DAP) developed by the authors, based on the modified sphygmomanometer method, from January to March 2002, the authors assessed 40 individuals with ages ranging from 25 to 66 years, divided into two groups: group I made up by individuals with unilateral knee pathologies with complaints of pain, and group II made up by volunteers with no history of disease or symptoms in the lower limbs. The DAP consists in an acrylic stand in which two other acrylic plates are mounted. A sphygmomanometer inflatable cuff was introduced between the base plate and each attached plate, and the reading of MMII pressure is made in the two analogical aneroids. Results: In group I, the difference of the pressure values between the healthy and the pathologic limbs was 30.15 mmHg. In group I, the average pressure in the healthy limb was significantly higher than the average pressure in the diseased limb (p < 0,05). In group II, there was no significant difference between the average pressures of the dominant and the contralateral limbs (p = 0.14). The mean asymmetry in group I was 15.61%, whereas it was only 0.72% in group II. Conclusion: An evaluation of the static pressure distribution between the MMII leads to the conclusion that there is a load transfer from the limb with a knee joint disease to the contralateral limb.
dc.identifier.citationVILLARDI, Alfredo Marques; VILLARDI, Ciríaco; CAMANHO, Gilberto Luís; CAGY, Maurício. Aplicação do dispositivo de avaliação pressórica na transferência de carga entre os membros inferiores nas doenças unilaterais do joelho. Revista Brasileira de Ortopedia. v.41. S10. p425-431. 2006
dc.identifier.issn1982-4378
dc.identifier.urihttps://ortobase.into.saude.gov.br/handle/123456789/452
dc.language.isopt
dc.publisherRevista Brasileira de Ortopedia
dc.subjectJoelho/Patologia
dc.subjectKnee/Pathology
dc.subjectExtremidade Inferior
dc.subjectLower Extremity
dc.subjectAvaliação/Métodos
dc.subjectEvaluation/ Methods
dc.subjectEsfigmomanômetros
dc.subjectSphygmomanometers
dc.subjectSuporte de Carga
dc.subjectWeight-Bearing
dc.titleAplicação do dispositivo de avaliação pressórica na transferência de carga entre os membros inferiores nas doenças unilaterais do joelho
dc.title.alternativeApplication of pressure evaluation device in assessing the load transfer between the lower limbs in unilateral pathologies of the knee joint
dc.typeArticle

Files

Original bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
Villardi, Alfredo Marques et al_2006.pdf
Size:
147.64 KB
Format:
Adobe Portable Document Format

License bundle

Now showing 1 - 1 of 1
Loading...
Thumbnail Image
Name:
license.txt
Size:
1.71 KB
Format:
Item-specific license agreed to upon submission
Description: