Abstract
Objective: To evaluate the Bear Hug maneuver for clinically diagnosing subscapularis tendon tears, and compare this with other maneuvers described previously (Lift-off, Napoleon and Belly Press).
Methods: Forty-nine patients with rotator cuff injuries who had undergone arthroscopy to repair the injury and had previously been assessed using the semiological maneuvers mentioned above were evaluated.
Results: The diagnostic values obtained for the Bear Hug test were as follows: sensitivity 75%, specificity 56%, positive predictive value 62%, negative predictive value 70% and accuracy 65%.
Conclusion: The highest sensitivity and negative predictive value values were obtained with the Bear Hug test. The highest specificity value was seen with the Lift-off test. The Belly press test gave the greatest specificity, positive predictive and accuracy values.
Description
Keywords
Citation
SCHIEFER, Márcio; JÚNIOR, Yonder Archanjo Ching San; SILVA, Sérgio Maurício; FONTENELLE, César; CARVALHO, Marcos Genúncio Dias; FARIA, Fabio Garcia de; FRANCO, José Sérgio. Clinical diagnosis of subscapularis tendon tear using the bear hug semiological maneuver. Revista Brasileira de Ortopedia. São Paulo. v.47. S5. p588-592. 2012 DOI 10.1016/S2255-4971(15)30008-2